CCPP Block at Power Plant EL-TO Zagreb
Purpose of the new CCPP Block is extension of power plant EL-TO to ensure safe and reliable supply of district heat, technological steam and electricity upon decommissioning of several existing units.
Services provided
- Establishment of Ebsilon@Professional model
- Establishment of Excel interface for plant performance calculations
- Heat and mass balance calculations
- Plant performance calculations
Key data
- Two (2) gas turbines (Siemens SGT-800 Gas, rated power 47 MW)
- Double pressure HRSG with supplementary firing
- One (1) condensing steam turbine, rated power 55 MW
- Fresh steam temperature: 520 °C
- Fresh steam pressure: 90 bar
- One (1) water cooled condenser, cooling output 130 MW
Time period: 2015