Analysis and optimization of CHP plant Janikowo
Conducting energy audit at CHP plant in Soda Production facility Janikowo and recommendation of appropriate measures for achieving energy savings.
Services provided:
-
Energy audit at CHP plant in Soda Production facility Janikowo
-
Collecting relevant technical data
-
Conducting thermodynamic and techno-economic calculations of CHP plant
-
Identification of appropriate measures for achieving energy savings
-
Preparation and elaboration of a report with technical and economic aspects of selected measures for achieving energy savings
Key data:
-
Three (3) coal fired steam boilers CKTI-85 (85 t/h, 420˚C, 38bar)
-
Two (2) coal fired steam boilers OP-140 (140 t/h, 500˚C, 96bar)
-
Back-pressure extraction steam turbine, rated power 7,5MW
-
Back-pressure extraction steam turbine, rated power 4MW
-
Back-pressure extraction steam turbine, rated power 7,8MW
-
Back-pressure extraction steam turbine, rated power 16,2MW
-
Back-pressure extraction steam turbine, rated power 20,5MW
-
Seven (7) pressure reducing stations
-
Four (4) steam collectors
Time period: 2014